Medical Gas Alarming System

Manufacturer of a wide range of products which include digital gas(o2, vac) alarm system, digital oxygen gas alarm for 1 gas, digital medical gas alarm 6 gases, digital gas alert alarm for 3 gases, 3 gas analog gas alarm and hospital oxygen gas(o2,vac,air,n2o) analoge type alarm.

Digital Gas(O2, Vac) Alarm System

  • Foil Print

₹ 6000/Piece Get Latest Price

Product Brochure
BrandMAP
MaterialMS Body with Antibacterial Powder Coated
Display TypeDigital Type
Distance50 meter
FuseYes
PanelPCB

Digital LED Gas Alert Alarm Specification MAP Brand for Hospital

1. General Requirements:

  • Purpose: To provide continuous digital monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 200 mm
    • Width: 300 mm
    • Depth: 70 mm
  • Design: Wall-mounted with a digital LED display.
  • Material: High-impact, flame-retardant MS Housing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life digital sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Color-coded LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
    • Distinct tones for different alarm conditions (low gas pressure, high gas pressure, system fault).
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: High-resolution LED display.
  • Information Displayed:
    • Real-time gas pressure levels.
    • Alarm status for each gas.
    • System status and fault indications.
  • User Interface:
    • Intuitive interface with easy navigation.
    • Test & Mute display settings.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz.
  • Power Consumption: ≤15W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP54

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016. (Medical Gas Pipeline Systems).
    • Compliance with NFPA 99 (Health Care Facilities Code).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance.
    •  Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.
    • On-site calibration capability with provided software and tools.

 

12. Warranty:

  • Standard Warranty: 1 years for all components.

Digital Oxygen Gas Alarm for 1 gas

  • Foil Print

₹ 3500/Unit Get Latest Price

Product Brochure
MaterialMedical
BrandMAP
Display TypeDigital
Distance50 meter
FuseYes
PanelPCB
Supply Voltage12 V
Gas TypeO2

Digital LED Gas Alert Alarm Specification MAP Brand for Hospital

1. General Requirements:

  • Purpose: To provide continuous digital monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 200 mm
    • Width: 300 mm
    • Depth: 70 mm
  • Design: Wall-mounted with a digital LED display.
  • Material: High-impact, flame-retardant MS Housing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life digital sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Color-coded LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
    • Distinct tones for different alarm conditions (low gas pressure, high gas pressure, system fault).
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: High-resolution LED display.
  • Information Displayed:
    • Real-time gas pressure levels.
    • Alarm status for each gas.
    • System status and fault indications.
  • User Interface:
    • Intuitive interface with easy navigation.
    • Test & Mute display settings.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz.
  • Power Consumption: ≤15W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP54

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016. (Medical Gas Pipeline Systems).
    • Compliance with NFPA 99 (Health Care Facilities Code).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance.
    •  Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.
    • On-site calibration capability with provided software and tools.

 

12. Warranty:

  • Standard Warranty: 1 years for all components.

13. Documentation:

  • Compliance Certificates: Provided for all relevant safety and performance standards.

Digital Medical Gas Alarm 6 gases

  • Foil Print

₹ 14500/Piece Get Latest Price

Power12 W
BrandMAP
MaterialMS Housing with Antibacterial Powder Coating
Usage/ApplicationHospital
Display TypeLED
Gas TypeMedical Gases
Horn Level85DB
Country of OriginMade in India

Minimum order quantity: 1 Piece

Digital LED Gas Alert Alarm Specification MAP Brand for Hospital

1. General Requirements:

  • Purpose: To provide continuous digital monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 275mm
    • Width: 415mm
    • Depth: 80mm
  • Design: Wall-mounted with a digital LED display.
  • Material: High-impact, flame-retardant MS Housing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life digital sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Color-coded LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
    • Distinct tones for different alarm conditions (low gas pressure, high gas pressure, system fault).
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: High-resolution LED display.
  • Information Displayed:
    • Real-time gas pressure levels.
    • Alarm status for each gas.
    • System status and fault indications.
  • User Interface:
    • Intuitive interface with easy navigation.
    • Test & Mute display settings.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz.
  • Power Consumption: ≤15W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP54

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016. (Medical Gas Pipeline Systems).
    • Compliance with NFPA 99 (Health Care Facilities Code).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance.
    •  Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.
    • On-site calibration capability with provided software and tools.

 

12. Warranty:

  • Standard Warranty: 1 years for all components.

13. Documentation:

  • Compliance Certificates: Provided for all relevant safety and performance standards.

Digital Gas Alert Alarm for 3 gases

  • Foil Print

₹ 8000/Piece Get Latest Price

Power12 W
BrandMAP
MaterialMS Body with Antibacterial Powder Coated
Usage/ApplicationHospital
Display TypeLED

Minimum order quantity: 1 Piece

Digital LED Gas Alert Alarm Specification MAP Brand for Hospital

1. General Requirements:

  • Purpose: To provide continuous digital monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 200 mm
    • Width: 300 mm
    • Depth: 70 mm
  • Design: Wall-mounted with a digital LED display.
  • Material: High-impact, flame-retardant MS Housing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life digital sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Color-coded LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
    • Distinct tones for different alarm conditions (low gas pressure, high gas pressure, system fault).
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: High-resolution LED display.
  • Information Displayed:
    • Real-time gas pressure levels.
    • Alarm status for each gas.
    • System status and fault indications.
  • User Interface:
    • Intuitive interface with easy navigation.
    • Test & Mute display settings.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz.
  • Power Consumption: ≤15W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP54

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016. (Medical Gas Pipeline Systems).
    • Compliance with NFPA 99 (Health Care Facilities Code).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance.
    •  Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.
    • On-site calibration capability with provided software and tools.

 

12. Warranty:

  • Standard Warranty: 1 years for all components.

13. Documentation:

  • Compliance Certificates: Provided for all relevant safety and performance standards.

3 Gas Analog Gas Alarm

₹ 7500/Piece Get Latest Price

Product Brochure
BrandMAP
MaterialMS
Display TypeAnalog Type
Distance50 meter
Frequency50Hz
FuseYes
PanelPCB Based
Supply Voltage220V
Number Of Zones2
MediaVacuum, O2

Analog Gas Alert Alarm Specification for Hospital MAP Brand 

1. General Requirements:

  • Purpose: To provide continuous monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 150 mm
    • Width: 250 mm
    • Depth: 50 mm
  • Design: Wall-mounted with an easy-to-read analog display.
  • Material: High-impact, flame-retardant MS Casing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Individual LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: Analog gauges for each gas type with clear, labeled scales.
  • Range:
    • Oxygen: 0-100 psi
    • Nitrous Oxide: 0-100 psi
    • Medical Air: 0-100 psi
    • Vacuum: 0-30 inHg
    • Carbon Dioxide: 0-100 psi
  • Accuracy: ±2% full scale.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz
    • 12V direct power supply
  • Power Consumption: ≤10W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP42

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016 (Medical Gas Pipeline Systems).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance and sensor replacement.
    • Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.

11. Warranty:

  • Standard Warranty: 1 years for all components

Hospital Oxygen Gas(O2,Vac,Air,N2O) Analoge Type Alarm

₹ 5500/Piece Get Latest Price

Product Brochure
BrandMAP
MaterialMedical
Display TypeAnalog Type
Distance50 meter
Fuseyes
Panel TypePCB

Analog Gas Alert Alarm Specification for Hospital MAP Brand 

1. General Requirements:

  • Purpose: To provide continuous monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 150 mm
    • Width: 250 mm
    • Depth: 50 mm
  • Design: Wall-mounted with an easy-to-read analog display.
  • Material: High-impact, flame-retardant MS Casing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Individual LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: Analog gauges for each gas type with clear, labeled scales.
  • Range:
    • Oxygen: 0-100 psi
    • Nitrous Oxide: 0-100 psi
    • Medical Air: 0-100 psi
    • Vacuum: 0-30 inHg
    • Carbon Dioxide: 0-100 psi
  • Accuracy: ±2% full scale.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz
    • 12V direct power supply
  • Power Consumption: ≤10W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP42

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016 (Medical Gas Pipeline Systems).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance and sensor replacement.
    • Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.

11. Warranty:

  • Standard Warranty: 1 years for all components

Analog 2 Gas Alert Alarm

₹ 5500/Piece Get Latest Price

Product Brochure
BrandMAP
MaterialMicro Processor Based Gas PCB
Usage/ApplicationMedical Use
Display TypeLED Display

Analog Gas Alert Alarm Specification for Hospital MAP Brand 

1. General Requirements:

  • Purpose: To provide continuous monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 150 mm
    • Width: 250 mm
    • Depth: 50 mm
  • Design: Wall-mounted with an easy-to-read analog display.
  • Material: High-impact, flame-retardant MS Casing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Individual LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: Analog gauges for each gas type with clear, labeled scales.
  • Range:
    • Oxygen: 0-100 psi
    • Nitrous Oxide: 0-100 psi
    • Medical Air: 0-100 psi
    • Vacuum: 0-30 inHg
    • Carbon Dioxide: 0-100 psi
  • Accuracy: ±2% full scale.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz
    • 12V direct power supply
  • Power Consumption: ≤10W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP42

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016 (Medical Gas Pipeline Systems).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance and sensor replacement.
    • Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.

11. Warranty:

  • Standard Warranty: 1 years for all components

Medical Oxygen Gas Failure Alarm with Valve Box Combo Unit for 2 - gases

  • Foil Print

₹ 9500/Piece Get Latest Price

MaterialSolid Brass , Copper , Metal Sheet
Display TypeDigital
Distance50 Mtrs
Frame TypeMetal Sheet Body with high quality powder coating
Supply Voltage12 volt
Usage/ApplicationHospital Use only
Warranty1 year

Minimum order quantity: 2 Piece

 Smart Digital Alarm + Valve Box Combo Unit 

  1. One Installation two functions.
  2. No additional Space or Sensor wiring required for alarm panels.
  3. Butterfly Valve R/N make is Installed to provide Convinient Operations
  4. Integrated microprocessor pressure sensor based digital alarm continously displays The monitored gas pressure.
  5. Cost effective & less space consumes compared to Seperate Digital alarm & Valve box.

1 Gas Medical Gas Alarm System Unit

₹ 1600/Piece Get Latest Price

Product Brochure
BrandMAP
MaterialM.S Steel
Display TypeAnalog Type
Distance50 meter
Usage/ApplicationHospitals
Number Of Zones1 In each
Country of OriginMade in India

Analog Gas Alert Alarm Specification for Hospital MAP Brand 

1. General Requirements:

  • Purpose: To provide continuous monitoring and alerting of medical gas levels and system status in hospital environments.
  • Location: To be installed in critical areas such as ICU, surgical suites, and recovery rooms.

2. Dimensions and Design:

  • Dimensions:
    • Height: 150 mm
    • Width: 250 mm
    • Depth: 50 mm
  • Design: Wall-mounted with an easy-to-read analog display.
  • Material: High-impact, flame-retardant MS Casing.
  • Finish: Smooth finish with antimicrobial Powder coating.

3. Gas Monitoring Capabilities:

  • Types of Gases Monitored:
    • Oxygen (O2)
    • Nitrous Oxide (N2O)
    • Medical Air
    • Vacuum (suction)
    • Carbon Dioxide (CO2)
  • Sensors: High-accuracy, long-life sensors specific to each gas type.

4. Alarm Specifications:

  • Visual Alarms:
    • Individual LED indicators for each gas (Green for normal, Yellow for warning, Red for alarm).
  • Audible Alarms:
    • Adjustable alarm volume with a minimum of 85 dB at 1 meter.
  • Alarm Conditions:
    • High/low gas pressure.
    • Sensor failure.
    • Power failure.

5. Display:

  • Type: Analog gauges for each gas type with clear, labeled scales.
  • Range:
    • Oxygen: 0-100 psi
    • Nitrous Oxide: 0-100 psi
    • Medical Air: 0-100 psi
    • Vacuum: 0-30 inHg
    • Carbon Dioxide: 0-100 psi
  • Accuracy: ±2% full scale.

6. Electrical Specifications:

  • Power Supply:
    • Input Voltage: 110-240V AC, 50/60Hz
    • 12V direct power supply
  • Power Consumption: ≤10W
  • Safety Standards: Compliant with IEC 60601-1 for medical electrical equipment.

7. Environmental Specifications:

  • Operating Temperature: 0°C to 50°C
  • Humidity: 0% to 95% RH, non-condensing
  • Ingress Protection: IP42

8. Installation and Mounting:

  • Mounting: Wall-mounted with included hardware.
  • Connections: Quick-connect fittings for gas lines and secure electrical connections.
  • Installation: To be installed by certified technicians.

9. Compliance and Safety:

  • Certifications:
    • CE marked.
    • Compliance with ISO 13485:2016 (Medical Gas Pipeline Systems).
  • Safety Features:
    • Overpressure protection.
    • Short-circuit protection.
    • Surge protection.

10. Maintenance and Calibration:

  • Maintenance:
    • User-friendly access for maintenance and sensor replacement.
    • Regular maintenance checks recommended every 6 months.
  • Calibration:
    • Factory calibrated with a recommended recalibration interval of 12 months.

11. Warranty:

  • Standard Warranty: 1 years for all components

X

Contact Us

Gajraj Rajput (Partner)
Medical Air Product
H. No. E-289/1 Basement & G/f Roop Nagar, Harsh Vihar, Jaitpur Sub Post Office, Hari Nagar Part 3, Badarpur
New Delhi - 110044, Delhi, India

Get Directions
Send Email
Share:
Thank youYour Enquiry has been sent successfully.