Zonal Valve Box Specification for Hospital
1. General Requirements:
- Purpose: To provide a central control point for isolating sections of the medical gas pipeline system in case of emergencies or maintenance.
- Location: To be installed in accessible areas such as corridors, utility rooms, and near nursing stations.
2. Dimensions and Design:
- Dimensions:
- Height: Variable based on the number of valves (typically 300 mm per valve row)
- Width: 400 mm
- Depth: 150 mm
- Design: Wall-mounted with a hinged door and clear front panel for easy visibility and access.
- Material: High-quality, corrosion-resistant stainless steel or powder-coated steel.
- Finish: Smooth finish with antimicrobial coating.
3. Valve Configuration:
- Number of Valves:
- Configurable based on the specific needs (typically 1 to 6 valves per box).
- Types of Valves:
- Ball valves or diaphragm valves compatible with medical gas systems.
- Gas Types Supported:
- Oxygen (O2)
- Nitrous Oxide (N2O)
- Medical Air
- Vacuum (suction)
- Carbon Dioxide (CO2)
- Other specialized medical gases as required.
4. Valve Specifications:
- Valve Material: Brass or stainless steel, compliant with ISO 7396-1 standards.
- Operation:
- Quarter-turn operation for quick isolation.
- Lockable handles to prevent unauthorized operation.
- Markings:
- Clear, permanent labeling for each gas type and direction of flow.
- Color-coded handles or labels per NFPA 99 standards.
5. Panel and Door Features:
- Front Panel:
- Clear, shatter-resistant acrylic or polycarbonate.
- Hinged for easy access to valves.
- Gasketed to prevent dust and contaminants.
- Door Lock:
- Key lock or tamper-evident seal.
- Emergency Access:
- Breakable glass panel for emergency access.
6. Pressure Gauges:
- Location: Integrated within the valve box, visible through the front panel.
- Type: Analog pressure gauges for each gas line.
- Range:
- Oxygen: 0-100 psi
- Nitrous Oxide: 0-100 psi
- Medical Air: 0-100 psi
- Vacuum: 0-30 inHg
- Carbon Dioxide: 0-100 psi
- Accuracy: ±2% full scale.
7. Compliance and Safety:
- Certifications:
- CE marked.
- Compliance with ISO 13485 (Medical Gas Pipeline Systems)..
- Safety Features:
- Overpressure protection.
- Clearly labeled emergency instructions.
- Proper grounding and bonding of metallic parts.
8. Installation and Mounting:
- Mounting: Wall-mounted with included hardware.
- Connections: Standardized inlet and outlet fittings for medical gas pipelines.
- Installation: To be installed by certified technicians.
9. Maintenance and Testing:
- Access: Easy access for maintenance and valve replacement.
- Service Intervals: Annual service recommended, or as per hospital maintenance schedule.
10. Warranty:
- Standard Warranty: 1 year for all components.